Rotex Automation Limited
Rotex Automation Limited
GIDC, Vadodara, Gujarat
SEND SMS
SEND EMAIL
 

Profile

Explosion Proof Solenoid With Junction Box 2

   
ROTEX AUTOMATION LIMITED is approved by Petrobras Brasil.. Under a category of Solenoid Valve, Pneumatic Valve, Pneumatic Cylinder.

Is Coil With Circuit 1

   

Coil Type

Atex

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

Marking :

Ex ia d IIC, T6, IP67

(- 40°Cto70°C)

 

 

Certificate No. : DNV-2005-OSL-ATEX-0191

 

Marking:

Ex II 1GD EEx ia d IIC, T6, IP 67 (- 40°Cto+70°C)

Ex I M1, EEx ia d IIC T6, IP 67 (- 40°Cto + 70°C)

Ex II 1GD EEx ia d IIC T6, IP 67 (- 40°Cto + 70°C)

(Type 62-01, 63-01, 64-01)

 

Standards:

EN50014, EN50018, EN50020,

EN50281-1-1, EN50284, EN5030

Low Power Is Coil

   

Coil Type

Atex

 

Low Power Is Coil

 

Marking:

 

EXd Enclosure

Ex ia d IIC, T6, IP67

(Type : 71, 72, 73)

 

TB Enclosure

Ex ia IIC T6, IP67

(Type : 66, 67, 68)

 

Plug in Enclosure

Ex ia IIC T6, IP67

(Type : 65CR)

 

Marking :

(- 40°C  to  70°C)

 

Certificate No. : DNV-2005-OSL-ATEX-0191

Marking:

Ex d Enclosure

Ex II 1GD EEx ia d IIC, T6, IP67(- 40°C to +70°C)

(Type:71-01, 71-01, 73-01,71-01-CO,72-01-CO,73-01-CO)

 

TB Enclosure

Ex I M1,EEx ia IIC T6, IP65(- 40°C to +70°C)

(Type:66-01, 67-01, 68-01, 66-01-CO,67-01-CO,68-01-CO)

 

Plug in Enclosure

Ex I M1,EEx ia IIC T6, IP67(- 40°C to +70°C)

(Type:65CR-01

 

Standards:

EN50014, EN50018, EN50020,EN50284,

EN50281-1-1,EN50303

Terminal Box

   

Coil Type

CMRI

 

Without LED

Type : 15, 16, 19

 

With LED

Type : 15-L, 16-L, 19-L

 

 

CMRI/TC//P/H685

Dtd.04.08.2003

 

CMRI/TC/S/H1243(Amendment for IP67) dtd. 03.02.2005

 

Standards:

IS-13947(Part-I) 1993

 

ERDA Certificate No.

PLV/06/IP/121 (IP 68) dtd. 20.04.2005

 

Standards:

IS:12063-(1987)

Explosion Proof Solenoid With Junction Box 1

   

Coil Type

CMRI

 

FJPBND - IIC

( Type : 36, 37, 39 )

 

Marking :

Ex d IIC, T4/T6 IP67

(- 40°C to 60°C)

(LED optionally provided)

 

 

CMRI/TC/P/H1415

dtd. 01.04.2005

 

Standards:

IS:2148-2004

(IEC 60079-1/2001)

 

ERDA Certificate No.

PLV/06/IP/122 (IP 68)

dtd. 20.04.2005

 

Standards:

IS:12063-(1987)

Coil With Circuit

   

Coil Type

CMRI

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

Marking :

Ex ia d IIC, T6, IP67 (- 40°C to 70°C)

 

 

CMRI/TC/S/H702

dtd. 13.12.2007

Standards:

IS:5780-2002

 

CMRI/TC/SR/H920

dtd. 08.03.2007

(Revalidation Certi. No. CMRI/TC/P/H84 dtd. Dtd .19.05.2005

 

Standards:

IS:2148-2004

Low Power Is Coil

   

Coil Type

CMRI

Low Power Is Coil

 

Marking :

 

Exd Enclousure

Ex ia d IIC, T6, IP67 ( Type : 71,72,73 )

 

TB Enclosure

Ex ia IIC T6, IP67 ( Type : 66, 67, 68 )

 

Plug In Enclosure

Ex ia IIC T6, IP67 ( Type : 65CR )

 

Marking :

(- 40°C to 0°C)

 

CMRI/TC/SR/H834

dtd. 08.02.2007 (Revalidation ofCMRI/TC/P/H87 dtd. 19.05.2005)

 

 

Standards:

IS:5780-2002

Entity Parameters amended vide

 

CIMFR/TC/S/H112

dtd. 22.05.2008

FJPBND-IIC

   

Coil Type

Gost

 

FJPBND - IIC

( Type : 36, 37, 39 )

 

Marking :

Exd IIC, T4/T6 IP67

(- 40°Cto60°C)

(LED optionally provided)

 

 

Certificate No. : POCC IN. 06.B00736

 

Marking :

Ex d IIC T6 IP66 (- 40°Cto35°C)

Type : (36-04, 37-04, 39-04, 36-04-CO, 37-04-CO, 39-04-CO

 

Standards :

IEC 60079, IEC 60529

(Equivalent to GOST R 52350)

Coil With Circuit

   

Coil Type

Gost

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

 

Marking :

Ex ia d IIC, T6, IP67

(- 40°Cto70°C)

 

 

Certificate No. : POCC IN. 06.B00736

 

Marking :

Ex ia IIC T6 IP 67,

Ex d IIC T6 IP 67

Type :(62-04, 63-04, 64-04,62-04-CO, 63-04-CO, 64-04-CO) (- 40°Cto +70°C)

 

 

Standards :

IEC 60079, IEC 60529

(Equivalent to GOST R52350)

 

Low Power Is Coil

   

Coil Type

Gost

Low Power Is Coil

 

Marking :

 

Exd Enclousure

Ex ia d IIC, T6, IP67 ( Type : 71,72,73 )

 

TB Enclosure

Ex ia IIC T6, IP67 ( Type : 66, 67, 68 )

 

lug In Enclosure

Ex ia IIC T6, IP67 ( Type : 65CR )

 

Marking :

(- 40°C to 70°C)

 

Certificate No. : POCC IN. 06.B00736

 

Marking :

 

Exd Enclousure

Ex[ia]d IIC T6 IP67 (- 40°C to + 70°C)

Type :(71-04, 72-04, 73-04, 71-04-CO, 72-04-CO, 73-04-CO)

 

TB Enclosure

Ex ia IIC T6 IP65 (- 40°C to + 70°C)

Type :(66-04, 67-04, 68-04, 66-04-CO, 67-04-CO, 68-04-CO)

 

Plug In Enclosure

EX ia IIC T6 IP67 (- 40°C to + 70°C)

Type : (65CR-04)

 

Standards : IEC 60079, IEC 60529

 

FJPBND-IIC

   

Coil Type

Inmetro

 

FJPBND - IIC

( Type : 36, 37, 39 )

 

Marking :

Exd IIC, T4/T6 IP67

(- 40°Cto60°C)

(LED optionally provided)

 

 

Certificate No. : CEPEL EX-1717/08X

 

Marking:

 

BR-Ex d IIC T* IP66

T4(- 40°Cto60°C)

T5(- 40°Cto50°C)

T6(- 40°Cto35°C)

(Type : 36-03, 37-03, 39-03,

36-03-CO, 37-03-CO, 39-03-CO)

 

Standards:

IEC 60079,IEC 60529

 

Coil With Circuit 1

   

Coil Type

Inmetro

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

Marking :

Ex ia d IIC, T6, IP67

(- 40°Cto70°C)

 

 

Certificate No. : CEPEL-EX-1718/08

 

Marking:

BR-Ex ia IIC T6 IP67

BR-Ex ia dIIC T6 IP67 (Type : 62-03, 63-03, 64-03, 62-03-CO, 63-03-CO, 64-03-CO)

(- 40°C to +70°C)

 

Standards:

IEC 60079, IEC 60529

 

Low Power Is Coil

   

Coil Type

Inmetro

Low Power Is Coil

Marking :

 

Exd Enclousure

Ex ia d IIC, T6, IP67 ( Type : 71,72,73 )

 

TB Enclosure

Ex ia IIC T6, IP67 ( Type : 66, 67, 68 )

 

Plug In Enclosure

Ex ia IIC T6, IP67 ( Type : 65CR )

 

Marking :

(- 40°Cto70°C)

 

Certificate No. : CEPEL-EX-1718/08

Marketing:

 

Ex d Enclosure
BR-Ex ia IIC T6 IP67(- 40°Cto70°C)

(Type :71-03, 72-03, 73-03,71-03-CO,72-03-CO, 73-03-CO)


TB Enclosure
BR-EX iad IIC T6 IP67 (- 40°Cto70°C)

(Type :66-03, 67-03, 68-03,66-03-CO,67-03-CO, 68-03-CO)

 

Plug In Enclosure
BR-EX iad IIC T6 IP65(- 40°Cto70°C)

Standards : IEC 60079, IEC 60529



Reach Us
Nautami Shah (Marketing Manager)
No. 987/11, GIDC Estate, Makarpura
Vadodara- 390010, Gujarat, India



Call Us

Share Us

F GT L


Send E-mailSend SMS