Rotex Automation Limited
Rotex Automation Limited
Makarpura, Vadodara, Gujarat
SEND SMS
SEND EMAIL
 

Profile

Company Factsheet


Basic Information
IndiaMART TrustSeal
Nature of Business
Manufacturer
Total Number of Employees
101 to 500 People
Year of Establishment
1983
Legal Status of Firm
Public Limited Company
Annual Turnover
Rs. 50 - 100 Crore
GST No.
24AABCR0011J1Z0
CIN No.
U29259GJ1983PLC005831

Explosion Proof Solenoid With Junction Box 2

Explosion Proof Solenoid With Junction Box 2
   
ROTEX AUTOMATION LIMITED is approved by Petrobras Brasil.. Under a category of Solenoid Valve, Pneumatic Valve, Pneumatic Cylinder.

Is Coil With Circuit 1

Is Coil With Circuit 1
   

Coil Type

Atex

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

Marking :

Ex ia d IIC, T6, IP67

(- 40°Cto70°C)

 

 

Certificate No. : DNV-2005-OSL-ATEX-0191

 

Marking:

Ex II 1GD EEx ia d IIC, T6, IP 67 (- 40°Cto+70°C)

Ex I M1, EEx ia d IIC T6, IP 67 (- 40°Cto + 70°C)

Ex II 1GD EEx ia d IIC T6, IP 67 (- 40°Cto + 70°C)

(Type 62-01, 63-01, 64-01)

 

Standards:

EN50014, EN50018, EN50020,

EN50281-1-1, EN50284, EN5030

Low Power Is Coil

Low Power Is Coil
   

Coil Type

Atex

 

Low Power Is Coil

 

Marking:

 

EXd Enclosure

Ex ia d IIC, T6, IP67

(Type : 71, 72, 73)

 

TB Enclosure

Ex ia IIC T6, IP67

(Type : 66, 67, 68)

 

Plug in Enclosure

Ex ia IIC T6, IP67

(Type : 65CR)

 

Marking :

(- 40°C  to  70°C)

 

Certificate No. : DNV-2005-OSL-ATEX-0191

Marking:

Ex d Enclosure

Ex II 1GD EEx ia d IIC, T6, IP67(- 40°C to +70°C)

(Type:71-01, 71-01, 73-01,71-01-CO,72-01-CO,73-01-CO)

 

TB Enclosure

Ex I M1,EEx ia IIC T6, IP65(- 40°C to +70°C)

(Type:66-01, 67-01, 68-01, 66-01-CO,67-01-CO,68-01-CO)

 

Plug in Enclosure

Ex I M1,EEx ia IIC T6, IP67(- 40°C to +70°C)

(Type:65CR-01

 

Standards:

EN50014, EN50018, EN50020,EN50284,

EN50281-1-1,EN50303

Terminal Box

Terminal Box
   

Coil Type

CMRI

 

Without LED

Type : 15, 16, 19

 

With LED

Type : 15-L, 16-L, 19-L

 

 

CMRI/TC//P/H685

Dtd.04.08.2003

 

CMRI/TC/S/H1243(Amendment for IP67) dtd. 03.02.2005

 

Standards:

IS-13947(Part-I) 1993

 

ERDA Certificate No.

PLV/06/IP/121 (IP 68) dtd. 20.04.2005

 

Standards:

IS:12063-(1987)

Explosion Proof Solenoid With Junction Box 1

Explosion Proof Solenoid With Junction Box 1
   

Coil Type

CMRI

 

FJPBND - IIC

( Type : 36, 37, 39 )

 

Marking :

Ex d IIC, T4/T6 IP67

(- 40°C to 60°C)

(LED optionally provided)

 

 

CMRI/TC/P/H1415

dtd. 01.04.2005

 

Standards:

IS:2148-2004

(IEC 60079-1/2001)

 

ERDA Certificate No.

PLV/06/IP/122 (IP 68)

dtd. 20.04.2005

 

Standards:

IS:12063-(1987)

Coil With Circuit

Coil With Circuit
   

Coil Type

CMRI

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

Marking :

Ex ia d IIC, T6, IP67 (- 40°C to 70°C)

 

 

CMRI/TC/S/H702

dtd. 13.12.2007

Standards:

IS:5780-2002

 

CMRI/TC/SR/H920

dtd. 08.03.2007

(Revalidation Certi. No. CMRI/TC/P/H84 dtd. Dtd .19.05.2005

 

Standards:

IS:2148-2004

Low Power Is Coil

Low Power Is Coil
   

Coil Type

CMRI

Low Power Is Coil

 

Marking :

 

Exd Enclousure

Ex ia d IIC, T6, IP67 ( Type : 71,72,73 )

 

TB Enclosure

Ex ia IIC T6, IP67 ( Type : 66, 67, 68 )

 

Plug In Enclosure

Ex ia IIC T6, IP67 ( Type : 65CR )

 

Marking :

(- 40°C to 0°C)

 

CMRI/TC/SR/H834

dtd. 08.02.2007 (Revalidation ofCMRI/TC/P/H87 dtd. 19.05.2005)

 

 

Standards:

IS:5780-2002

Entity Parameters amended vide

 

CIMFR/TC/S/H112

dtd. 22.05.2008

FJPBND-IIC

FJPBND-IIC
   

Coil Type

Gost

 

FJPBND - IIC

( Type : 36, 37, 39 )

 

Marking :

Exd IIC, T4/T6 IP67

(- 40°Cto60°C)

(LED optionally provided)

 

 

Certificate No. : POCC IN. 06.B00736

 

Marking :

Ex d IIC T6 IP66 (- 40°Cto35°C)

Type : (36-04, 37-04, 39-04, 36-04-CO, 37-04-CO, 39-04-CO

 

Standards :

IEC 60079, IEC 60529

(Equivalent to GOST R 52350)

Coil With Circuit

Coil With Circuit
   

Coil Type

Gost

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

 

Marking :

Ex ia d IIC, T6, IP67

(- 40°Cto70°C)

 

 

Certificate No. : POCC IN. 06.B00736

 

Marking :

Ex ia IIC T6 IP 67,

Ex d IIC T6 IP 67

Type :(62-04, 63-04, 64-04,62-04-CO, 63-04-CO, 64-04-CO) (- 40°Cto +70°C)

 

 

Standards :

IEC 60079, IEC 60529

(Equivalent to GOST R52350)

 

Low Power Is Coil

Low Power Is Coil
   

Coil Type

Gost

Low Power Is Coil

 

Marking :

 

Exd Enclousure

Ex ia d IIC, T6, IP67 ( Type : 71,72,73 )

 

TB Enclosure

Ex ia IIC T6, IP67 ( Type : 66, 67, 68 )

 

lug In Enclosure

Ex ia IIC T6, IP67 ( Type : 65CR )

 

Marking :

(- 40°C to 70°C)

 

Certificate No. : POCC IN. 06.B00736

 

Marking :

 

Exd Enclousure

Ex[ia]d IIC T6 IP67 (- 40°C to + 70°C)

Type :(71-04, 72-04, 73-04, 71-04-CO, 72-04-CO, 73-04-CO)

 

TB Enclosure

Ex ia IIC T6 IP65 (- 40°C to + 70°C)

Type :(66-04, 67-04, 68-04, 66-04-CO, 67-04-CO, 68-04-CO)

 

Plug In Enclosure

EX ia IIC T6 IP67 (- 40°C to + 70°C)

Type : (65CR-04)

 

Standards : IEC 60079, IEC 60529

 

FJPBND-IIC

FJPBND-IIC
   

Coil Type

Inmetro

 

FJPBND - IIC

( Type : 36, 37, 39 )

 

Marking :

Exd IIC, T4/T6 IP67

(- 40°Cto60°C)

(LED optionally provided)

 

 

Certificate No. : CEPEL EX-1717/08X

 

Marking:

 

BR-Ex d IIC T* IP66

T4(- 40°Cto60°C)

T5(- 40°Cto50°C)

T6(- 40°Cto35°C)

(Type : 36-03, 37-03, 39-03,

36-03-CO, 37-03-CO, 39-03-CO)

 

Standards:

IEC 60079,IEC 60529

 

Coil With Circuit 1

Coil With Circuit 1
   

Coil Type

Inmetro

 

Is Coil With Circuit

( Type : 62, 63, 64 )

 

Marking :

Ex ia d IIC, T6, IP67

(- 40°Cto70°C)

 

 

Certificate No. : CEPEL-EX-1718/08

 

Marking:

BR-Ex ia IIC T6 IP67

BR-Ex ia dIIC T6 IP67 (Type : 62-03, 63-03, 64-03, 62-03-CO, 63-03-CO, 64-03-CO)

(- 40°C to +70°C)

 

Standards:

IEC 60079, IEC 60529

 

Low Power Is Coil

Low Power Is Coil
   

Coil Type

Inmetro

Low Power Is Coil

Marking :

 

Exd Enclousure

Ex ia d IIC, T6, IP67 ( Type : 71,72,73 )

 

TB Enclosure

Ex ia IIC T6, IP67 ( Type : 66, 67, 68 )

 

Plug In Enclosure

Ex ia IIC T6, IP67 ( Type : 65CR )

 

Marking :

(- 40°Cto70°C)

 

Certificate No. : CEPEL-EX-1718/08

Marketing:

 

Ex d Enclosure
BR-Ex ia IIC T6 IP67(- 40°Cto70°C)

(Type :71-03, 72-03, 73-03,71-03-CO,72-03-CO, 73-03-CO)


TB Enclosure
BR-EX iad IIC T6 IP67 (- 40°Cto70°C)

(Type :66-03, 67-03, 68-03,66-03-CO,67-03-CO, 68-03-CO)

 

Plug In Enclosure
BR-EX iad IIC T6 IP65(- 40°Cto70°C)

Standards : IEC 60079, IEC 60529

zoomup


Reach Us
Pratik Parikh (Engineer)
No. 987/11, GIDC Estate, Makarpura
Vadodara- 390010, Gujarat, India



Call Us

Share Us

F GT L


Send E-mailSend SMS